National Repository of Grey Literature 2 records found  Search took 0.01 seconds. 
Current source for measuring purposes
Chevalier, Stanislav ; Vorel, Pavel (referee) ; Patočka, Miroslav (advisor)
Goal of this semestral thesis is to design power converter which is to be used for measurement. The converter consists of two forward converters in push-pull topology. The converter is to behave as a constant current source with maximum open-circuit voltage of 1000V. Maximum current is 5A. The current range is split into three sub-ranges, to meet the strict requirements on ripple current. The range of currents is 0-5A. The operating frequency of converter is 34KHz. The converter will be charged using two portable electric generators with output voltage 230V.
Current source for measuring purposes
Chevalier, Stanislav ; Vorel, Pavel (referee) ; Patočka, Miroslav (advisor)
Goal of this semestral thesis is to design power converter which is to be used for measurement. The converter consists of two forward converters in push-pull topology. The converter is to behave as a constant current source with maximum open-circuit voltage of 1000V. Maximum current is 5A. The current range is split into three sub-ranges, to meet the strict requirements on ripple current. The range of currents is 0-5A. The operating frequency of converter is 34KHz. The converter will be charged using two portable electric generators with output voltage 230V.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.